A new measurement device is useful only if its readings agree with the method already used in practice. The Bland-Altman plot is the standard graphical method to assess this agreement between two methods that measure the same continuous variable. It shows the average difference between the methods (the bias) and the range in which most differences lie (the limits of agreement). However, a common mistake is to use a correlation coefficient instead. Two methods can be highly correlated and still disagree by a clinically important amount. This guide explains the Bland-Altman plot step by step, using one hypothetical clinical example.
Table of Contents
Working on a study? StatisMed biostatisticians can run your analysis, calculate your sample size, and write your Results section. Get a free quote →
What Is a Bland-Altman Plot?
A Bland-Altman plot is a scatter plot of the differences between two paired measurements against their mean. Each point represents one patient. Three horizontal lines are then added: the mean difference and the upper and lower 95% limits of agreement (Giavarina, 2015).
The Bias (Mean Difference)
The bias is the mean of all the differences between the two methods. It shows whether one method gives systematically higher or lower values than the other. Notably, a small bias alone does not prove agreement, because positive and negative differences cancel each other.
The 95% Limits of Agreement
The limits of agreement are calculated as the bias ± 1.96 × the standard deviation (SD) of the differences. About 95% of the differences between the two methods are expected to lie between these limits. Therefore, the limits show how far a single measurement by the new method may differ from the reference method in an individual patient.
Variants of the Bland-Altman Plot
The classic plot uses absolute differences, such as mmHg or mg/dL. When the differences grow with the size of the measurement, the differences can be expressed as a percentage of the mean, or the data can be log-transformed and the results reported as ratios. In addition, a modified version exists for studies with repeated measurements on the same patient.
Importance of Bland-Altman Analysis in Medical Research
Validating New Measurement Devices
New devices, such as point-of-care glucose meters, are often cheaper, faster or less invasive than the reference method. Bland-Altman analysis shows whether the new device can replace the reference method in clinical practice.
Separating Agreement from Correlation
The Pearson correlation coefficient measures the strength of a linear relationship, not agreement. For example, if one method always gives values 20 units higher than the other, the correlation is perfect, but the methods do not agree. Moreover, the correlation becomes larger when the range of values in the sample is wide (Doğan, 2018).
Linking Statistics to Clinical Decisions
The limits of agreement are expressed in the original units of measurement. Therefore, clinicians can compare them directly with the largest difference that is acceptable in practice.
Applications of the Bland-Altman Plot in Clinical Studies
Method Comparison Studies
The most common use is the comparison of a new method with a reference method in the same patients. An example is cardiac output by echocardiography versus thermodilution.
Laboratory Medicine
In clinical laboratories, Bland-Altman analysis is used to compare two analyzers, two assays or two sample types.
Inter-Rater and Test-Retest Agreement
The same plot can assess agreement between two observers who measure the same patients, or between two measurements by one observer at different times. In contrast, agreement between raters on categorical scales needs other methods, and the internal consistency of questionnaires is assessed with Cronbach’s alpha.
Assumptions of the Bland-Altman Plot
Before you build a Bland-Altman plot, check that the data meet the following conditions:
- Both methods measure the same continuous variable in the same units.
- Each patient is measured by both methods at the same time, or close enough that the true value does not change.
- The differences between the methods are approximately normally distributed.
- The bias and the spread of the differences are constant across the range of measurements (no proportional bias).
- Each patient contributes one pair of measurements, unless a method for repeated measurements is used.
- The clinically acceptable limits of agreement are defined before the analysis.
How to Perform a Bland-Altman Plot: A Clinical Example
Consider a hypothetical method comparison study in 40 adult patients in an intensive care unit. Systolic blood pressure (SBP) was measured at the same time by an automated oscillometric cuff (the new method) and by an intra-arterial line (the reference method). The mean intra-arterial SBP was 128.2 mmHg (SD 17.4), and the mean cuff SBP was 124.1 mmHg (SD 18.2). All the numbers below were calculated with Python.
Step 1: Define the Clinically Acceptable Limits
The acceptable limits must be set before the data are analyzed. In this example, the investigators decided that a difference of up to ±10 mmHg between the cuff and the arterial line is clinically acceptable. Notably, the plot itself does not tell you whether the agreement is good.
Step 2: Calculate the Mean and the Difference for Each Patient
For each patient, calculate the mean of the two methods and the difference between them. In this example, the difference is cuff minus arterial line, so a negative value means that the cuff gave a lower reading. Table 1 shows the first 8 of the 40 patients.
| Patient | Arterial line (mmHg) | Cuff (mmHg) | Mean (mmHg) | Difference, cuff − arterial (mmHg) |
|---|---|---|---|---|
| 1 | 132 | 126 | 129.0 | −6 |
| 2 | 122 | 111 | 116.5 | −11 |
| 3 | 119 | 121 | 120.0 | 2 |
| 4 | 82 | 80 | 81.0 | −2 |
| 5 | 159 | 153 | 156.0 | −6 |
| 6 | 151 | 144 | 147.5 | −7 |
| 7 | 122 | 114 | 118.0 | −8 |
| 8 | 145 | 139 | 142.0 | −6 |
Step 3: Check the Distribution of the Differences
The differences ranged from −15 to 10 mmHg. The Shapiro-Wilk test showed no departure from normality (W = 0.984, p = 0.841). In addition, a linear regression of the differences on the means showed no proportional bias (slope = 0.043, 95% CI, −0.052 to 0.137, p = 0.367). Therefore, the classic Bland-Altman method with absolute differences is appropriate.
Step 4: Calculate the Bias and Its 95% Confidence Interval
The sum of the 40 differences was −166 mmHg, so the bias was −166 ÷ 40 = −4.15 mmHg. The SD of the differences was 5.14 mmHg. The 95% CI of the bias is the bias ± t × SD ÷ √n, where t = 2.023 for 39 degrees of freedom. This gives a 95% CI of −5.79 to −2.51 mmHg. Moreover, a one-sample t-test (equivalent to a paired t-test) showed that the bias was significantly different from zero (t = −5.10, df = 39, p < 0.001). However, this p-value shows only that the bias is not zero, not that it is clinically important.
Step 5: Calculate the 95% Limits of Agreement
First, 1.96 × 5.14 = 10.08 mmHg. Therefore, the lower limit of agreement is −4.15 − 10.08 = −14.23 mmHg, and the upper limit is −4.15 + 10.08 = 5.93 mmHg. Each limit also needs its own 95% CI. The approximate standard error of each limit is √(3 × SD² ÷ n) = 1.41 mmHg. As a result, the 95% CI was −17.08 to −11.38 mmHg for the lower limit and 3.08 to 8.78 mmHg for the upper limit.
| Measure | Calculation | Estimate (mmHg) | 95% CI (mmHg) |
|---|---|---|---|
| Bias (mean difference) | −166 ÷ 40 | −4.15 | −5.79 to −2.51 |
| SD of the differences | — | 5.14 | — |
| Lower limit of agreement | −4.15 − 1.96 × 5.14 | −14.23 | −17.08 to −11.38 |
| Upper limit of agreement | −4.15 + 1.96 × 5.14 | 5.93 | 3.08 to 8.78 |
| Differences within ±10 mmHg | 36 ÷ 40 | 90.0% | — |
Step 6: Draw the Bland-Altman Plot
Plot the mean of each pair on the horizontal axis and the difference on the vertical axis. Then add a solid line for the bias and dashed lines for the two limits of agreement. In this example, 3 of the 40 points (7.5%) lie outside the limits of agreement, and the spread of the points is similar across the range of SBP values (Figure 1).

Step 7: Compare the Limits with the Clinical Limits
The upper limit of agreement (5.93 mmHg) lies inside the acceptable limit of +10 mmHg. However, the lower limit (−14.23 mmHg) lies outside the acceptable limit of −10 mmHg. Therefore, the cuff can underestimate SBP by more than 10 mmHg in some patients. Notably, the Pearson correlation between the two methods was very high (r = 0.959, p < 0.001), which shows again that a high correlation does not mean good agreement.
How to Report a Bland-Altman Plot in a Manuscript
In the Methods section, state the reference method, the direction of the difference, the clinically acceptable limits and the method for the confidence intervals. For example: “Agreement was assessed with a Bland-Altman plot, with differences calculated as cuff minus arterial line.” In the Results section, report the findings clearly, as in the model paragraph below.
Agreement Between Oscillometric and Intra-Arterial Systolic Blood Pressure
Systolic blood pressure measured by the oscillometric cuff was significantly lower than the intra-arterial measurement (MD = −4.15 mmHg, 95% CI, −5.79 to −2.51, p < 0.001). The lower 95% limit of agreement was −14.23 mmHg (95% CI, −17.08 to −11.38), and the upper limit was 5.93 mmHg (95% CI, 3.08 to 8.78). Moreover, the lower limit of agreement exceeded the predefined acceptable limit of −10 mmHg. In addition, 36 of the 40 differences (90.0%) were within ±10 mmHg (Table 2).
Notice that the paragraph gives the numbers without any statement about the clinical use of the cuff device. The interpretation and the comparison with previous studies belong in the Discussion section.
Common Mistakes When Using the Bland-Altman Plot
Using Correlation to Show Agreement
A high correlation coefficient only shows that the two methods move together. In this example, r was 0.959, yet the lower limit of agreement was outside the acceptable range. Therefore, never use the correlation coefficient alone as evidence of agreement.
Not Defining Acceptable Limits in Advance
Without predefined limits, any result can be called “acceptable” after the analysis. State the clinical limits, taken from guidelines or the literature, in the study protocol.
Ignoring Proportional Bias
When the differences increase or decrease with the size of the measurement, a single pair of limits is misleading. In that case, use percentage differences, a log transformation or regression-based limits of agreement.
Reporting Limits Without Confidence Intervals
The limits of agreement are estimates from a sample, and their confidence intervals are wide in small samples. Plan an adequate sample size before the study, and report the 95% CI of the bias and of each limit.
Running a Bland-Altman Plot in SPSS and R
In SPSS, first create two new variables with Transform → Compute Variable: the mean of the two methods and their difference. Next, use Analyze → Descriptive Statistics → Descriptives to obtain the mean and SD of the difference, and calculate the limits. Then draw the scatter plot with Graphs → Chart Builder → Scatter/Dot, and add reference lines at the bias and the limits.
In R, the plot needs one line of base code: d <- cuff - art; plot((cuff + art) / 2, d); abline(h = mean(d) + c(-1.96, 0, 1.96) * sd(d)). If the differences are not normally distributed, the nonparametric limits based on the 2.5th and 97.5th percentiles can be used, and the Wilcoxon signed-rank test can replace the t-test for the bias.
Conclusion
The Bland-Altman plot is the standard method to assess agreement between two methods of measurement. It shows the bias and the 95% limits of agreement in the original units, so the results can be compared directly with clinically acceptable limits. Furthermore, a complete report includes the bias, both limits, their 95% confidence intervals, a check for proportional bias and the plot itself.
If you are not sure which statistical test to choose, or you need help with a method comparison study, the StatisMed team of biostatisticians provides statistical analysis services for medical studies. You can request a free quote today.
Frequently Asked Questions
1. How do you interpret a Bland-Altman plot?
First, look at the bias line to see whether one method gives systematically higher or lower values. Second, look at the limits of agreement and compare them with the clinically acceptable limits. Finally, check whether the spread of the points changes across the range of measurements.
2. What sample size is needed for Bland-Altman analysis?
There is no single rule. However, the confidence intervals of the limits of agreement are wide in small samples. In this example, with 40 patients, each limit had a 95% CI of about ±2.85 mmHg. A formal sample size calculation can be based on the expected SD of the differences and the acceptable limits.
3. What is the difference between Bland-Altman analysis and the intraclass correlation coefficient?
Bland-Altman analysis gives the bias and the limits of agreement in the original units of measurement. In contrast, the intraclass correlation coefficient is a unitless index of reliability between 0 and 1. Only the Bland-Altman plot can be compared directly with clinical limits.
References
Doğan, N. Ö. (2018). Bland-Altman analysis: A paradigm to understand correlation and agreement. Turkish Journal of Emergency Medicine, 18(4), 139–141. https://doi.org/10.1016/j.tjem.2018.09.001
Giavarina, D. (2015). Understanding Bland Altman analysis. Biochemia Medica, 25(2), 141–151. https://doi.org/10.11613/BM.2015.015